Overview
carafe models the low-temperature plasmas of negative-ion sources, neutralizers and magnetrons at three levels of detail: volume-averaged (0D) balances of every species and the electron energy, 1D and 2D fluids of the same species on a grid, and the inductive RF field that heats them. The same reactions drive all of them, so a model can be checked against the level below it.
Each equation on these pages is declared on the code that implements it, as a method card, and checked by the tests: 26 closed forms against SymPy rules and seven discretisations against their order of convergence. The pages of the section list the cards module by module; this one shows how they fit together.
The global models
Section titled “The global models”- Reactions run at , with rate coefficients from plasmacoll’s cross sections (Maxwellian averages), fits, or the collisional-radiative tables of OpenCR.
- Global model: the particle balance of every species, quasi-neutrality, Bohm losses through the walls (with an edge-to-centre ratio and cusp leak widths), the electron energy with the sheath of floating walls, and optionally the gas temperature. The steady state is a pseudo-time integration in the logarithms of the unknowns, polished by a root finder:
GlobalModel
classsourceThe balances of a plasma in a chamber; see the module docstring.
- particles
- sources
- ion wall loss
- neutral wall loss
- electron wall loss
- energy
- wall energy
- sheath
- Assumes
- a uniform plasma with Maxwellian electrons; Bohm losses need the chamber
- the stoichiometric change, the change per source event, the feed (1/s), the pumping speed (unknown neutrals only)
- negative ions do not reach the walls; the Bohm speed carries no factor
- the presheath is per ion and the sheath drop per charge, the same only for
- floored at 1 m in the energy equation; a fixed species' is reported, not integrated
- References
- Lieberman and Lichtenberg, Principles of Plasma Discharges and Materials Processing, 2nd ed. (2005), ch. 10
- Built from
- Three devices are global models with their own closures: the neutralizer (a fast beam’s charge states on the gas and its plasma, iterated to a fixed point), the RF driver (the transformer model of the coil, with Nagaoka’s coefficient and the exact solenoid as reference) and the magnetron (the ionization region with sputtering, the sputter wind and secondary-electron heating). The ionization region model (IRM) of a HiPIMS pulse is the fuller version of the magnetron: thermal and hot electrons, cold, warm and hot argon with metastables and Ar2+, the metal with M+ and M2+, ohmic heating by the share of the discharge voltage over the region and back-attraction of the ions to the target, driven by the measured and ; are fitted to the discharge current:
IonizationRegion
classsourceThe ionization region model of a HiPIMS discharge; see the module docstring.
- geometry
- quasineutrality
- ions
- neutrals
- target
- hot electrons
- current
- energy
- outputs
- Assumes
- a uniform annulus over the racetrack; the measured , drive it, and are fitted
- two electron groups: Maxwellian thermal electrons with an energy equation, hot electrons at a fixed that thermalize after losing
- ions leave at the Bohm speed of the thermal electrons (no factor ); a share of them returns to the target
- Ar ions return as hot Ar from the target and as warm Ar from the bulk (probability
warm_return); metal ions stick - newborn electrons carry no energy; electrons leave for the bulk with ; the cold gas flows in at the filling density
- rate coefficients, yields, secondary yields, temperatures of the atom groups and the geometry are PLACEHOLDERS
- References
- Built from
The fluid models
Section titled “The fluid models”- Fluid 1D: drift-diffusion of every species with Scharfetter-Gummel fluxes, the electron energy equation and Poisson’s equation, ions optionally with inertia; backward Euler and Newton’s method:
Fluid1D
classsourceA plasma between x = 0 and length on cells cells; see the module docstring.
- continuity
- energy
- poisson
- momentum
- losses
- grid
- staggered
- Order
- 2
- Assumes
- unless given ( for electrons, otherwise); constant transport coefficients; no gas or ion energy equation
- Scharfetter-Gummel fluxes on uniform cells; on a face with the mean of its cells; the Joule term the mean of on the two faces
- a momentum ion: its face velocity an unknown, upwinded on the cells, its force times the SG flux with ; without inertia the SG flux exactly
- the rate of the reactions destroying it (ions born at rest); Poisson's equation needs the Debye length resolved
- the order is that of a steady diffusion problem with held densities (the problem of the tests)
- References
- Built from
- Fluid 2D on the cells of a cell grid (a cut or r–z, tensor or refined patches): inertial ions with Rusanov fluxes, quasi-neutral with sheath walls or with Poisson’s equation, heated and pushed by the RF field.
- Inductive field 2D: the magnetoquasistatic field of the coil and a cold or viscous electron plasma, time-harmonic or stepped in time; in 3D on a Yee edge grid with surface-impedance conductors on cut cells, solved directly or by COCG.
- Field and plasma are iterated to the absorbed or the generator power; the neutral gas (H and H2 as Navier-Stokes fluids with kinetic walls) is iterated with the plasma.
The magnetron plane
Section titled “The magnetron plane”- Drift fluid 2D: the axial-azimuthal plane with Hall-tensor electrons, inertial ions, the gas and full Poisson, stepped by SSP-RK3 with an implicit permittivity, optionally with the sputtered metal (atoms and singly charged ions, self-sputtering and a secondary yield per ion species); its linear modes and the local dispersion relations (cold or kinetic ions) and the nonlocal eigenmodes across a 1D profile (drift-fluid, inertial or gyro-averaged electrons) describe the gradient-drift instability behind the spokes.
- Gas dynamics: argon and the sputtered metal as one compressible gas (MUSCL, HLLC, SSP-RK3), driven by the sputter wind; the gas and drift fluid are split on windows, the plasma’s ionization and returned ions driving the gas and the gas setting the plasma’s .
- The transport budget is a diagnostic of PIC moments: the -averaged momentum identity of the cross-field flux.
Units and conventions
Section titled “Units and conventions”Temperatures in eV ( stands for ), everything else SI; GasDynamics takes its
temperatures in K. Time-harmonic fields are amplitudes of . In a 2D cut,
volumes, powers and currents are per metre along (a device’s are depth times them);
in r–z they are totals. In the magnetron plane runs from the cathode to the anode and
along ; gradient lengths are signed.
Not in the models
Section titled “Not in the models”- No Boltzmann-electron closure: the electrons are always a drift-diffusion fluid;
quasi-neutrality only in
Fluid2D. GlobalModel: a uniform plasma with Maxwellian electrons; the edge-to-centre ratio is an input; per-ion and per-charge wall energies mix for .Fluid1D: constant transport coefficients, no gas or ion energy equation.Fluid2D: ions at , a fixed gas unless coupled, no volume sources with an electron energy.- The inductive field: no displacement current, no in-plane drift force in the momentum balance, no viscous time stepper; the 0D driver has no stochastic heating, shields or mutual coupling.
DriftFluid2D: no electron inertia, no electron-ion or ion-ion collisions, no race-track curvature, no gas temperature; of the metal, no doubly charged ions, no electron collisions with the atoms but their ionization, and the atoms a beam along .Magnetron: no metastables, no multiply charged ions, no gas heating.GasDynamicsandNeutralFluid2Dare continuum models at Knudsen numbers of 0.1 to 1, without a kinetic check.- Several data sets are placeholders, said where they are used: the illustrative hydrogen driver and deuterium neutralizer, the magnetron materials, the drift fluid’s argon rates.
Verification
Section titled “Verification”Besides the checks of the cards, the tests compare the global model’s balances with closed
forms (Te from the particle balance, negative ions, wall recombination), the neutralizer’s
fractions with plasmacoll’s, the transformer model with the Bessel column it is the thin-skin
limit of, Fluid2D on a slab with Fluid1D to round-off and with ambipolar and
collisionless closed forms, the coupled fluid column with the global model, the 2D field with
line currents, loops, solenoids and conducting columns, the 3D field with its 2D limit and
cut cells with planes and tubes, the neutral gas with its 0D limit, the drift fluid’s growth
rates with its local dispersion relation, and the gas dynamics with Sod’s problem and its
conservation.